I'm working on adding a requested feature to my SPA. We have some users who leave their tabs open to our application for long periods of time. We also push out frequent updates (sometimes 5x a day, as we're pre-revenue). I'm wondering if it's possible to modify the serviceWorker that comes installed with Create-React-App to run a polling loop (maybe every 10 minutes) to poll for new updates to the application, instead of only on initial page load.
This way, a user who leaves their tab open could receive update notifications without having to refresh.
Has anyone achieved something like this before, and know how I might implement that into the CRA serviceWorker?
Figured it out! In the registerServiceWorker.js file, I added a simple setInterval inside the callback for the navigator.serviceWorker.register() function:
// poll for live updates to the serviceWorker
pollingLoopInterval = setInterval(async () => {
await registration.update();
}, POLLING_LOOP_MS);
Easy!
Related
I'm playing with the service worker API in my computer so I can grasp how can I benefit from it in my real world apps.
I came across a weird situation where I registered a service worker which intercepts fetch event so it can check its cache for requested content before sending a request to the origin.
The problem is that this code has an error which prevented the function from making the request, so my page is left blank; nothing happens.
As the service worker has been registered, the second time I load the page it intercepts the very first request (the one which loads the HTML). Because I have this bug, that fetch event fails, it never requests the HTML and all I see its a blank page.
In this situation, the only way I know to remove the bad service worker script is through chrome://serviceworker-internals/ console.
If this error gets to a live website, which is the best way to solve it?
Thanks!
I wanted to expand on some of the other answers here, and approach this from the point of view of "what strategies can I use when rolling out a service worker to production to ensure that I can make any needed changes"? Those changes might include fixing any minor bugs that you discover in production, or it might (but hopefully doesn't) include neutralizing the service worker due to an insurmountable bug—a so called "kill switch".
For the purposes of this answer, let's assume you call
navigator.serviceWorker.register('service-worker.js');
on your pages, meaning your service worker JavaScript resource is service-worker.js. (See below if you're not sure the exact service worker URL that was used—perhaps because you added a hash or versioning info to the service worker script.)
The question boils down to how you go about resolving the initial issue in your service-worker.js code. If it's a small bug fix, then you can obviously just make the change and redeploy your service-worker.js to your hosting environment. If there's no obvious bug fix, and you don't want to leave your users running the buggy service worker code while you take the time to work out a solution, it's a good idea to keep a simple, no-op service-worker.js handy, like the following:
// A simple, no-op service worker that takes immediate control.
self.addEventListener('install', () => {
// Skip over the "waiting" lifecycle state, to ensure that our
// new service worker is activated immediately, even if there's
// another tab open controlled by our older service worker code.
self.skipWaiting();
});
/*
self.addEventListener('activate', () => {
// Optional: Get a list of all the current open windows/tabs under
// our service worker's control, and force them to reload.
// This can "unbreak" any open windows/tabs as soon as the new
// service worker activates, rather than users having to manually reload.
self.clients.matchAll({type: 'window'}).then(windowClients => {
windowClients.forEach(windowClient => {
windowClient.navigate(windowClient.url);
});
});
});
*/
That should be all your no-op service-worker.js needs to contain. Because there's no fetch handler registered, all navigation and resource requests from controlled pages will end up going directly against the network, effectively giving you the same behavior you'd get without if there were no service worker at all.
Additional steps
It's possible to go further, and forcibly delete everything stored using the Cache Storage API, or to explicitly unregister the service worker entirely. For most common cases, that's probably going to be overkill, and following the above recommendations should be sufficient to get you in a state where your current users get the expected behavior, and you're ready to redeploy updates once you've fixed your bugs. There is some degree of overhead involved with starting up even a no-op service worker, so you can go the route of unregistering the service worker if you have no plans to redeploy meaningful service worker code.
If you're already in a situation in which you're serving service-worker.js with HTTP caching directives giving it a lifetime that's longer than your users can wait for, keep in mind that a Shift + Reload on desktop browsers will force the page to reload outside of service worker control. Not every user will know how to do this, and it's not possible on mobile devices, though. So don't rely on Shift + Reload as a viable rollback plan.
What if you don't know the service worker URL?
The information above assumes that you know what the service worker URL is—service-worker.js, sw.js, or something else that's effectively constant. But what if you included some sort of versioning or hash information in your service worker script, like service-worker.abcd1234.js?
First of all, try to avoid this in the future—it's against best practices. But if you've already deployed a number of versioned service worker URLs already and you need to disable things for all users, regardless of which URL they might have registered, there is a way out.
Every time a browser makes a request for a service worker script, regardless of whether it's an initial registration or an update check, it will set an HTTP request header called Service-Worker:.
Assuming you have full control over your backend HTTP server, you can check incoming requests for the presence of this Service-Worker: header, and always respond with your no-op service worker script response, regardless of what the request URL is.
The specifics of configuring your web server to do this will vary from server to server.
The Clear-Site-Data: response header
A final note: some browsers will automatically clear out specific data and potentially unregister service workers when a special HTTP response header is returned as part of any response: Clear-Site-Data:.
Setting this header can be helpful when trying to recover from a bad service worker deployment, and kill-switch scenarios are included in the feature's specification as an example use case.
It's important to check the browser support story for Clear-Site-Data: before your rely solely on it as a kill-switch. As of July 2019, it's not supported in 100% of the browsers that support service workers, so at the moment, it's safest to use Clear-Site-Data: along with the techniques mentioned above if you're concerned about recovering from a faulty service worker in all browsers.
You can 'unregister' the service worker using javascript.
Here is an example:
if ('serviceWorker' in navigator) {
navigator.serviceWorker.getRegistrations().then(function (registrations) {
//returns installed service workers
if (registrations.length) {
for(let registration of registrations) {
registration.unregister();
}
}
});
}
That's a really nasty situation, that hopefully won't happen to you in production.
In that case, if you don't want to go through the developer tools of the different browsers, chrome://serviceworker-internals/ for blink based browsers, or about:serviceworkers (about:debugging#workers in the future) in Firefox, there are two things that come to my mind:
Use the serviceworker update mechanism. Your user agent will check if there is any change on the worker registered, will fetch it and will go through the activate phase again. So potentially you can change the serviceworker script, fix (purge caches, etc) any weird situation and continue working. The only downside is you will need to wait until the browser updates the worker that could be 1 day.
Add some kind of kill switch to your worker. Having a special url where you can point users to visit that can restore the status of your caches, etc.
I'm not sure if clearing your browser data will remove the worker, so that could be another option.
I haven't tested this, but there is an unregister() and an update() method on the ServiceWorkerRegistration object. you can get this from the navigator.serviceWorker.
navigator.serviceWorker.getRegistration('/').then(function(registration) {
registration.update();
});
update should then immediately check if there is a new serviceworker and if so install it. This bypasses the 24 hour waiting period and will download the serviceworker.js every time this javascript is encountered.
For live situations you need to alter the service worker at byte-level (put a comment on the first line, for instance) and it will be updated in the next 24 hours. You can emulate this with the chrome://serviceworker-internals/ in Chrome by clicking on Update button.
This should work even for situations when the service worker itself got cached as the step 9 of the update algorithm set a flag to bypass the service worker.
We had moved a site from godaddy.com to a regular WordPress install. Client (not us) had a serviceworker file (sw.js) cached into all their browsers which completely messed things up. Our site, a normal WordPress site, has no service workers.
It's like a virus, in that it's on every page, it does not come from our server and there is no way to get rid of it easily.
We made a new empty file called sw.js on the root of the server, then added the following to every page on the site.
<script>
if (navigator && navigator.serviceWorker && navigator.serviceWorker.getRegistration) {
navigator.serviceWorker.getRegistration('/').then(function(registration) {
if (registration) {
registration.update();
registration.unregister();
}
});
}
</script>
In case it helps someone else, I was trying to kill off service workers that were running in browsers that had hit a production site that used to register them.
I solved it by publishing a service-worker.js that contained just this:
self.globalThis.registration.unregister();
I have a simple PWA, that I update and change from Github pages.
When I make an update to the website, It doesn't show on the devices using the website, because (at least I think) its being cached. I don't have any service workers to cache the site.
Even a normal refresh from the website (using all of these)
Doesn't refresh it and shows the changes. On iOS I manually have to go into settings and clear the website data to see the changes.
How can i fix this?
Use Network First (Network Falling Back to Cache)
https://developers.google.com/web/tools/workbox/modules/workbox-strategies#network_first_network_falling_back_to_cache
For requests that are updating frequently, the network first strategy is the ideal solution. By default, it will try to fetch the latest response from the network. If the request is successful, it’ll put the response in the cache. If the network fails to return a response, the cached response will be used.
When you make a page reload, a new check is done to verify if a new SW version is available.
However you need then to close all your app browser tabs in order to install the new service worker version.
In Chrome Dev Tools you can check the "Update on Reload" checkbox on the Application tab. This is useful for development.
I would suggest to read the Google docs about it.
Plus, if you want to learn more details about PWAs have a look at my articles.
UPDATE
The browser checks for updates automatically after navigations (at latest every 24h). However you can also trigger the update manually (for example you can have a timer and trigger it once per hour or according to your needs):
navigator.serviceWorker.register('/sw.js').then(reg => {
// ...
// Trigger this after your timeout
reg.update();
});
Alternatively you can use the updatefound event in order to detect in your code that a new sw version in available:
The onupdatefound property of the ServiceWorkerRegistration interface is an EventListener property called whenever an event of type statechange is fired; it is fired any time the ServiceWorkerRegistration.installing property acquires a new service worker.
navigator.serviceWorker.register('/sw.js').then(reg => {
reg.addEventListener('updatefound', () => {
const newSW = reg.installing;
newSW.addEventListener('statechange', () => {
// Check service worker state
if (newSW.state === 'installed') {
// A new SW is available and installed.
// You can update the page directly or better
// show a notification to the user to prompt for a page reload
// and inform about the new version available
}
});
});
});
I'm using Angular 5 for building a web application and would like to know if I can re-initialize the entire application OR use something like:
ApplicationRef.tick();
to execute all the changes that happens after a specific event. The event is my scenario is authentication token renewal, because for some reason my application's change detection starts breaking unless I run each action inside
NgZone.run()
(I'm using ADAL for authentication in case anybody is interested), but when the token is renewed (using a hidden iframe) the application change detection, routing, etc starts breaking. But when the page is refreshed it starts working perfectly fine till the next time token expires and ADAL has to create an iFrame to renew the token. So I was thinking if at least I could re-initialize the application after the token is renewed so that user doesn't have to refresh the application manually (till I find a more solid solution).
You can call the change detection explictly like below.
constructor(private changeDetector: ChangeDetectorRef) {
this.someEvents.subscribe((data) => {
this.changeDetector.detectChanges();
} );
}
https://angular.io/api/core/ChangeDetectorRef
It's mandatory, if you are calling any third party API or executing third party library Codes. We need to manually call ngzone.run(), which will internally call ApplicationRef.tick() to notify angular to perform change detection from Application root component to the child component (i.e whole application).
ngZone.run(()=>{
// Adal callback Function
});
If you are need to trigger change detection only to the current component and their childrens (not whole application). You can use any one option.
1) setTimeout(()=>{}, 0);
2) this.cdr.detectChanges();
3) For Components with OnPush Change Detection Stratergy, you can call this.cdr.markForCheck() inside setTimeout();
setTimeout(()=>{
this.cdr.markForCheck();
}, 0);
I'm playing with the service worker API in my computer so I can grasp how can I benefit from it in my real world apps.
I came across a weird situation where I registered a service worker which intercepts fetch event so it can check its cache for requested content before sending a request to the origin.
The problem is that this code has an error which prevented the function from making the request, so my page is left blank; nothing happens.
As the service worker has been registered, the second time I load the page it intercepts the very first request (the one which loads the HTML). Because I have this bug, that fetch event fails, it never requests the HTML and all I see its a blank page.
In this situation, the only way I know to remove the bad service worker script is through chrome://serviceworker-internals/ console.
If this error gets to a live website, which is the best way to solve it?
Thanks!
I wanted to expand on some of the other answers here, and approach this from the point of view of "what strategies can I use when rolling out a service worker to production to ensure that I can make any needed changes"? Those changes might include fixing any minor bugs that you discover in production, or it might (but hopefully doesn't) include neutralizing the service worker due to an insurmountable bug—a so called "kill switch".
For the purposes of this answer, let's assume you call
navigator.serviceWorker.register('service-worker.js');
on your pages, meaning your service worker JavaScript resource is service-worker.js. (See below if you're not sure the exact service worker URL that was used—perhaps because you added a hash or versioning info to the service worker script.)
The question boils down to how you go about resolving the initial issue in your service-worker.js code. If it's a small bug fix, then you can obviously just make the change and redeploy your service-worker.js to your hosting environment. If there's no obvious bug fix, and you don't want to leave your users running the buggy service worker code while you take the time to work out a solution, it's a good idea to keep a simple, no-op service-worker.js handy, like the following:
// A simple, no-op service worker that takes immediate control.
self.addEventListener('install', () => {
// Skip over the "waiting" lifecycle state, to ensure that our
// new service worker is activated immediately, even if there's
// another tab open controlled by our older service worker code.
self.skipWaiting();
});
/*
self.addEventListener('activate', () => {
// Optional: Get a list of all the current open windows/tabs under
// our service worker's control, and force them to reload.
// This can "unbreak" any open windows/tabs as soon as the new
// service worker activates, rather than users having to manually reload.
self.clients.matchAll({type: 'window'}).then(windowClients => {
windowClients.forEach(windowClient => {
windowClient.navigate(windowClient.url);
});
});
});
*/
That should be all your no-op service-worker.js needs to contain. Because there's no fetch handler registered, all navigation and resource requests from controlled pages will end up going directly against the network, effectively giving you the same behavior you'd get without if there were no service worker at all.
Additional steps
It's possible to go further, and forcibly delete everything stored using the Cache Storage API, or to explicitly unregister the service worker entirely. For most common cases, that's probably going to be overkill, and following the above recommendations should be sufficient to get you in a state where your current users get the expected behavior, and you're ready to redeploy updates once you've fixed your bugs. There is some degree of overhead involved with starting up even a no-op service worker, so you can go the route of unregistering the service worker if you have no plans to redeploy meaningful service worker code.
If you're already in a situation in which you're serving service-worker.js with HTTP caching directives giving it a lifetime that's longer than your users can wait for, keep in mind that a Shift + Reload on desktop browsers will force the page to reload outside of service worker control. Not every user will know how to do this, and it's not possible on mobile devices, though. So don't rely on Shift + Reload as a viable rollback plan.
What if you don't know the service worker URL?
The information above assumes that you know what the service worker URL is—service-worker.js, sw.js, or something else that's effectively constant. But what if you included some sort of versioning or hash information in your service worker script, like service-worker.abcd1234.js?
First of all, try to avoid this in the future—it's against best practices. But if you've already deployed a number of versioned service worker URLs already and you need to disable things for all users, regardless of which URL they might have registered, there is a way out.
Every time a browser makes a request for a service worker script, regardless of whether it's an initial registration or an update check, it will set an HTTP request header called Service-Worker:.
Assuming you have full control over your backend HTTP server, you can check incoming requests for the presence of this Service-Worker: header, and always respond with your no-op service worker script response, regardless of what the request URL is.
The specifics of configuring your web server to do this will vary from server to server.
The Clear-Site-Data: response header
A final note: some browsers will automatically clear out specific data and potentially unregister service workers when a special HTTP response header is returned as part of any response: Clear-Site-Data:.
Setting this header can be helpful when trying to recover from a bad service worker deployment, and kill-switch scenarios are included in the feature's specification as an example use case.
It's important to check the browser support story for Clear-Site-Data: before your rely solely on it as a kill-switch. As of July 2019, it's not supported in 100% of the browsers that support service workers, so at the moment, it's safest to use Clear-Site-Data: along with the techniques mentioned above if you're concerned about recovering from a faulty service worker in all browsers.
You can 'unregister' the service worker using javascript.
Here is an example:
if ('serviceWorker' in navigator) {
navigator.serviceWorker.getRegistrations().then(function (registrations) {
//returns installed service workers
if (registrations.length) {
for(let registration of registrations) {
registration.unregister();
}
}
});
}
That's a really nasty situation, that hopefully won't happen to you in production.
In that case, if you don't want to go through the developer tools of the different browsers, chrome://serviceworker-internals/ for blink based browsers, or about:serviceworkers (about:debugging#workers in the future) in Firefox, there are two things that come to my mind:
Use the serviceworker update mechanism. Your user agent will check if there is any change on the worker registered, will fetch it and will go through the activate phase again. So potentially you can change the serviceworker script, fix (purge caches, etc) any weird situation and continue working. The only downside is you will need to wait until the browser updates the worker that could be 1 day.
Add some kind of kill switch to your worker. Having a special url where you can point users to visit that can restore the status of your caches, etc.
I'm not sure if clearing your browser data will remove the worker, so that could be another option.
I haven't tested this, but there is an unregister() and an update() method on the ServiceWorkerRegistration object. you can get this from the navigator.serviceWorker.
navigator.serviceWorker.getRegistration('/').then(function(registration) {
registration.update();
});
update should then immediately check if there is a new serviceworker and if so install it. This bypasses the 24 hour waiting period and will download the serviceworker.js every time this javascript is encountered.
For live situations you need to alter the service worker at byte-level (put a comment on the first line, for instance) and it will be updated in the next 24 hours. You can emulate this with the chrome://serviceworker-internals/ in Chrome by clicking on Update button.
This should work even for situations when the service worker itself got cached as the step 9 of the update algorithm set a flag to bypass the service worker.
We had moved a site from godaddy.com to a regular WordPress install. Client (not us) had a serviceworker file (sw.js) cached into all their browsers which completely messed things up. Our site, a normal WordPress site, has no service workers.
It's like a virus, in that it's on every page, it does not come from our server and there is no way to get rid of it easily.
We made a new empty file called sw.js on the root of the server, then added the following to every page on the site.
<script>
if (navigator && navigator.serviceWorker && navigator.serviceWorker.getRegistration) {
navigator.serviceWorker.getRegistration('/').then(function(registration) {
if (registration) {
registration.update();
registration.unregister();
}
});
}
</script>
In case it helps someone else, I was trying to kill off service workers that were running in browsers that had hit a production site that used to register them.
I solved it by publishing a service-worker.js that contained just this:
self.globalThis.registration.unregister();
I want my package to stop meteor hot code reloads. I do this in my package to achieve that:
Reload._onMigrate('LiveUpdate', function(retry) {
console.log("RELOADING LIVe UPDATE");
return [false];
});
Problem is that Meteor would call this only once. I need to call "retry" function to call it again.
What I want to achieve is that above function would get called every time a change happens on the filesystem, but Meteor won't actually refresh the page. How can achieve that?
OK I found a solution myself. This is how it goes:
// stopping reloads on file changes and calling refreshPage after initial app is loaded,
// i.e after the user has loaded the app, and has changed some file
Reload._onMigrate("LiveUpdate", function() {
Deps.autorun(function() {
Autoupdate.newClientAvailable();
console.log("NEW CLIENT AVAILABLE. YAY!!");
LiveUpdate.refreshPage();
});
return [false];
});
AutoUpdate package itself does something similar. Meteor creates and uses a collection (ClientVersions) for keeping record of changes on client (and similar is used for server). AutoUpdate package triggers reload Reload package when the computation invalidates and stop it right after that. Because of the I wasn't getting any notifications even when I overrode Reload._reload. So I ran my own reactive computation and used Autoupdate.newClientAvailable() to invalidate it whenever new changes are available. I wonder what are the reasons for which Meteor decides to stop the computation after one trigger only. I bet they have solid reasons for doing that. I am yet to face them.
you need to add on the client this code:
Meteor._reload.onMigrate(function() {
return [false];
});
How can I disable live reload in meteor?